SVN Hour meters

   -2

SVN-2 hour meters measure and display the operating hours digitally to ensure the timely maintenance and monitoring of the remaining service life of the tractor and road-building machinery, equipment, electrical installations and units (UV bactericidal devices, machine tools, chillers, compressors, stand-alone power plants, pumps, generators. etc.).

The elapsed time metered in real-time hours is displayed on a digital LED or LCD display accurate to tenths of an hour, if activated. In case of power failure, the readings will be stored in the nonvolatile memory.

The meters (depending on their version) are fed from a power supply of 12/24 VDC or 230 VAC.

Versions

SVN-2-3.1, SVN-2-3.2, SVN-2-05.1, SVN-2-05.2

The elapsed time is counted and displayed on a non- stop basis (if activated).

SVN-2-01-3.1, SVN-2-3.21

The elapsed time is counted only if the DC or AC voltage is fed at the additional terminal C (to count the operating hours when the motor is on or when the equipment operates in a particular mode).

SVN-2-02-3.1, SVN-2-3.22

The elapsed time is counted only if the AC voltage is fed at the additional terminal C (e. g. AC voltage of the generator or speed sensor), thus minimizing the risk of unauthorized increase in operating hours.
Features
  • high accuracy
  • 6-digit LED display, 9.2 mm high
  • silent operation no moving parts
  • wide voltage ranges
  • reliability due to nonvolatile memory (EEPROM) which retains data for 25 years
  • low power consumption

The non-resettable 6-digit elapsed time recorder displays time up to 99,999.9 hours. Operable in wide temperature span from minus 40 to plus 70 C° and have hermetic package class IP65. Iinterchangeability with electromechanical indicators.

It has bezel with four holes for flush panel mounting.

Versions

Parameter Value
SVN-2-3.1
SVN-2-01-3.1
SVN-2-02-3.1
SVN-2-3.2
SVN-2-3.21
SVN-2-3.22
SVN-2-05.1 SVN-2-05.2
Rated voltage 12 and 24 VDC 220-230 ADC
Display LED LCD,
backlight
LED LCD, backlight
Visible area 43x12 mm 36x14 mm 43x12 mm 6x14 mm
Digit height 9,2 mm 9 mm 9,2 mm 9 mm

Technical Data

Parameter Value
SVN-2-3.1
SVN-2-01-3.1
SVN-2-02-3.1
SVN-2-3.2
SVN-2-3.21
SVN-2-3.22
SVN-2-05.1 SVN-2-05.2
Operating voltage range 10 ... 36 V 187 ... 253 V
Hour meter capacity 100 000 h
Readings resolution 0.1 h (6 min)
Counting resolution 1 s
Operating temperature range -40 ... +55 °C
Counting accuracy:
- within the temperature range of -20...+55 °C up to ±1 %
- within the temperature range of -40...+55 °C up to ±2 %
Max allowed voltage at the output C ±50 V
Count activation voltage at the input D (except for SVN-2-3.1):
- DC up to +1,5 V
- AC (ampl.), 5 Hz...10 kHz up to +1,5 V
Input C impedance 10 kOhm
Power consumption up to 2 W up to 3 VA
Allowed vibratory loads:
- max acceleration up to 50 m/s 2
- frequency range 50 ... 250 Hz
Protection degree according to GOST 14254
(except for electrical connectors)
IP65 IP5X
Dimensions (without mating contacts) up to 60x60x29 mm up to 60x60x37 mm
Weight up to 45 g up to 60 g

Dimensions [mm]

Technical description
PDF, 1,2 MB


Phone/fax: +7 (351) 731-30-00, 222-47-77
Nakhiimova st., 19p, Chelyabinsk, 454119, Russian federation