Pressure transducer TKN series

Features
  • resistance to aggressive media (working parts made of stainless steel)
  • high stability and reliability reading
  • high stability to triple overload pressure
  • modification whith current and digital output signal
  • waterproof steel housing

Pressure transducer TKN series provides measurement to excessive pressure in the range 0–1000 atm. liquid and gasiform environment in control and regulation systems, used in mechanical engineering, instrument engineering as well as another branch.

Ordering Code

    TKN   25 T   1   3   2 3    
Series title                                             Additional customer options: (might be missing)
Upper-range value (Mpa)                                             Pipe connection
1 — M22×1,5 (IEC 22525-77)
2 — G 1/4" (DIN 3852-E)
3 — K 1/8" (IEC 6111-52, NPT 1/8")
4 — K 1/4" (IEC 6111-52, NPT 1/4")
5 — M10×1
6 — M20×1,5 - 6 g
Signal output:
E — voltage signal
T — current signal
P — digital interface
                                           
Interface:
For current signal:
1 — 4–20 mA
2 — 0–20 mA
For digital interface:
1 — RBus
2 — CANopen
For voltage signal:
1 — 0,5–4,5 V
2 — 0–5 V
                          Electrical Connection:
0 — without connector
1 — AMP Superseal plug 1.5 (4 contacts)
2 — 2PM 14BPN4H1V1 plug
3 — M12×1 plug (4 contacts)
4 — SNC-42-10/10V-1-V plug GEO.364.245 TU
5 — AMP Superseal plug 1.5 (2 contacts)
6 — GSA plug 3000 (DIN 43650-A, ISO4400)
7 — GSA plug 3000 (DIN 43650-C, ISO15217)
8 — MP Superseal plug 1.5 (3 contacts)
9 — Q14-4ZPJ plug (4 contacts)

Technical Data

Measuring range 0-2,5 ... 0-100 Mpa
Main measuring accuracy  
  • TKNxx-E1xx, TKNxx-E2xx,TKNxx-T1xx, TKNxx-T2xx
    ±1;%
    • TKNxx-P1xx, TKNxx-P2xx
      ±0.2%
      Complementary temperature error at every 10°C
      • TKNxx-E1xx, TKNxx-E2xx,TKNxx-T1xx, TKNxx-T2xx
        ±0,15%
        • TKNxx-P1xx, TKNxx-P2xx
          ±0,08%
          Sability to pressure overload threefold, any more 150 MPa
          Supply voltage 10 – 32 V
          Temperature range  
          • operation
            – 40 to +55 °C
            • storage
              – 50 to +65 °C
              Protection class (to IEC 14254-96) IP67
              Vibration resistance - peak acceleration <50 m/sec2 (at 0…250 Hz)
              Impact resistance 150 m/sec2
              Dimensions 70 × 24 mm
              Weight, approx. 0,5 kg

              Dimensions [mm]

              Technical manual pressure transducer TKN series
              PDF, 770 Kb


              Phone/fax: +7 (351) 731-30-00, 222-47-77
              Mashinostroitelei st., 10-b, Chelyabinsk, 454119, Russian federation