Features
|
![]() |
Pressure transducer TKN series provides measurement to excessive pressure
TKN | 25 | – | T | 1 | 3 | 2 | – | 3 | |||||||||||||||||
Series title | Additional customer options: (might be missing) | ||||||||||||||||||||||||
Upper-range value (Mpa) | Pipe connection
1 M22×1,5 (IEC 22525-77) 2 G 1/4" (DIN 3852-E) 3 K 1/8" (IEC 6111-52, NPT 1/8") 4 K 1/4" (IEC 6111-52, NPT 1/4") 5 M10×1 6 |
||||||||||||||||||||||||
Signal output:
E voltage signal
T current signal P digital interface |
|||||||||||||||||||||||||
Interface:
For voltage signal:
1 0,54,5 V 2 05 V | Electrical Connection:
0 without connector 1 2 2PM 14BPN4H1V1 plug 3 M12×1 plug (4 contacts) 4 SNC-42-10/10V-1-V plug GEO.364.245 TU 5 6 GSA plug 3000 (DIN 43650-A, ISO4400) 7 GSA plug 3000 (DIN 43650-C, ISO15217) 8 MP Superseal plug 1.5 (3 contacts) 9 Q14-4ZPJ plug (4 contacts) |
Measuring range | 0-2,5 ... 0-100 Mpa |
Main measuring accuracy | |
|
±1;% |
|
±0.2% |
Complementary temperature error |
|
|
±0,15% |
|
±0,08% |
Sability to pressure overload | threefold, any more 150 MPa |
Supply voltage | 10 32 V |
Temperature range | |
|
40 to +55 °C |
|
50 to +65 °C |
Protection class (to IEC 14254-96) | IP67 |
Vibration resistance - peak acceleration | <50 m/sec2 (at 0…250 Hz) |
Impact resistance | 150 m/sec2 |
Dimensions | 70 × 24 mm |
Weight, approx. | 0,5 kg |
![]() |
Technical manual pressure transducer TKN series PDF, |
![]() |