Your friends will be grateful:
Liquid Level Sensors DT7.3
Features:
  • protections from vibrations, shocks and high temperatures
  • hight reliability
  • no movable parts
  • version with RBus, CANopen and RS-485 interfaces

The liquid level sensor provides measurement of diesel oil level (or petrol level or others) in fuel tanks.

The level sensors are manufactured with measuring tube length from 300 until 1000 mm.

Ordering Code

    DT7 . 3 С L    
Type                           Measuring tube length, mm
Serie
«3» — flange mounting, 16 way male AMP Superseal 1.5 plug
                           
Output signal:
«01» — 0,5 – 4,5 V;
«02» — 4 – 20 mA;
«03» — RBus interface;
«04» — RS-485;
«05» — CANopen.
                         
                         

Technical Data

Parameter Value
Measuring range 10 to 1000 mm
Accuracy of level measurement ±1%
Supply voltage 10 – 32 V DC
Maximum consumed power  
  • DT7.3-01, DT7.3-02, DT7.3-03 versions
    0,8 Wt (with gauge — 4 Wt)
    • DT7.3-04 version (without control lamp)
      0,2 Wt
      Operating temperature range – 40…+55 °C
      Storage/Transport temperature range – 50…+65 °C
      Protection class (to IEC 60529) IP67
      Vibration resistance <50 m/sec2 (at 50…200 Hz)
      Shock resistance <100 m/sec2
      Dimensions (without measuring tube length), height × diameter 22 × 66 mm
      Weight, approx. (L — measuring tube length) 300+0,435×L kg

      Dimensions [mm]

      Connection Scheme

      © 2000–2019 Rezonans