Features:
- measurement of stretching force until 1000 kgf
- high accuracy
- temperature compensation
- very good operating reliability under extreme conditiones
- digital interface
- one discrete input
|
|
The tension force transducer DS1000.12 provides measurement of stretching force until 1000 kgf.
It was designed for mobile control and rated capacity limiter systems.
Technical Data
| Measuring range |
0 to 1000 kgf |
| Accuracy |
1% FS typ. |
| Sensor deformation type |
stretching |
| Load limit |
1500 kgf (during 2 min) |
| Connection interface |
RBus |
| Connector |
AMP Superseal 1.5 plug |
| Supply voltage |
8 – 32 V DC |
| Operating temperature range |
– 40…+65 °C |
| Storage/Transport temperature range |
– 60…+80 °C |
| Protection class (to IEC 60529) |
IP56 |
| Vibration resistance |
<50 m/sec2 (at 50…200 Hz) |
| Impact resistance |
<100 m/sec2 |
| Dimensions |
267 × 90 × 55 mm |
| Weight, approx. |
1,1 kg |
Dimensions [mm]
|